Model NO.: VS1
Trademark: HEMG
Transport Package: Wooden Case
Specification: 24kv
Origin: China

Â
item | Description | Unit |
PEDEEE Requirements |
Bidder Specification |
1 | Manufacturer reputation/skills/quality check | Â | Â | HEMG |
2 | ISO9001 Certificate | Â | Â | ISO |
3 | Type of circuit breaker | Â | Â | VACUUM |
4 | Type designation | Â | Â | INDOOR |
5 | Rated frequency | Hz | 60 | 60 |
6 |
Rated voltage
|
kV kV |
17Â Â Â Â Â Â Â Â Â Â Â Â Â 20 |
24Â Â Â Â Â Â Â Â Â Â Â Â Â 20 |
7 |
Rated normal current at 50ºC ambient temperature
|
AÂ Â Â Â Â A |
≥630 ≥1250 |
≥630 ≥1250 |
8 |
Rated breaking current capacity
|
 |
20 |
25 |
9 | Rated peak making current, kA (peak) |  | ≥62.5 | ≥62.5 |
10 | Rated peak short-circuit current, kA (peak) | Â | Â | 50 |
11 |
Rated short time current
|
 |
≥25 |
≥25 |
12 | Rated line charging breaking current | A |  |  |
13 | Rated cable charging breaking current | A | Â | 25 |
14 | Rated small inductive breaking current | A | Â | Â |
15 | Rated breaking current under out of phase conditions | kA | Â | 17.4 |
16 |
Restricting voltage
|
 |  |  |
17 | Fist pole to clear factor | Â | Â | 1.5 |
18 |
One minute power frequency withstand voltage phase to earth, kV(rms)
|
 |
≥50 ≥50 |
65 65 Â |
19 | Lighting impulse withstand voltage 1.2/50 microsecond |  | ≥125 | 125 |
20 | Rated operating sequence | Â | Â | O-0.3s-CO-180s-CO |
21 | Capacity to make | Â | Â | 75 |
High speed three phase auto recluse | Â | Â | Â | |
22 | Minimum time between each successive break/make operation | Sec |  | ≤2 |
23 |
Opening time (until separation of the arcing contacts
|
ms ms |
 |
50 50 |
24 |
Maximum total break time (until total are extinction) |
ms |  | ≤50 |
25 | Maximum time interval between opening of the fist and last phase | ms |  | ≤2 |
26 | Maximum time interval between opening of the interrupters of one phase (if any) | ms | Â | Â |
27 |
Make tine
|
ms ms |
 |  |
28 | Maximum total make time (closing initiation to latching of circuit breaker in fully closed position) | ms |  | ≤75 |
29 | Maximum time between closing of fist and last phase | ms |  | ≤2 |
30 | Maximum time interval between closing of interrupters of one phase | ms | Â | Â |
31 | Dead time | ms | ≤300 | ≤300 |
32 | Maximum peak value of switching over voltage when interrupting rated line charging current, kV(peak) | Â | Â | Â |
33 | Radio influence voltage (RIV) measured at rated voltage to earth, micro V | Â | Â | Â |
34 | Devices used to limit transient recovery voltages | Â | Â | Â |
35 |
Creepage distance
|
 |  |  |
36 |
Operating mechanism type
|
VDC % |
220,110 -20 +10 |
220,110 -20 +10 |
37 |
Closing release coil
|
VDC % % W |
220,110 -20% +10 Â |
220,110 -20% +10 Â |
38 |
Trip release coil rated operating voltage
|
VDC % % W |
220,110 -30% +10% Â |
220,110 -30% +10% Â |
39 |
Distance:Â
|
 |  |
275mm  |
40 |
Weight of circuit breakerÂ
|
 |  |
138kg |
41 |
Type certificate details:
|
 |  | YES |
42 | The interrupter vacuum cubicle/country of origin |  |  | CHINA |
Draw-wire sensors of the wire sensor series measure with high linearity across the entire measuring range and are used for distance and position measurements of 100mm up to 20,000mm. Draw-wire sensors from LANDER are ideal for integration and subsequent assembly in serial OEM applications, e.g., in medical devices, lifts, conveyors and automotive engineering.
Linear Encoder,Digital Linear Encoder,Draw Wire Sensor,1500Mm Linear Encoder